 |
 |
 |
 |
The compact BW Gas Alert Micro Confined Space Kit with 5-Gas Detector will sense up to 5 potentially lethal gasses at a time
Features & Applications: GasAlertMicro5 PID portable gas detector simultaneously monitors up to five atmospheric hazards including volatile organic compounds (VOCs), oxygen, combustible gas (% LEL), and a wide selection of individual electrochemical toxic sensors. Compact and lightweight, GasAlertMicro5 PID activates audible, visual and vibrating alarms in the event of a low, high, TWA or STEL alarm condition.
VOCs present multiple potential threats in the workplace environment. VOCs are characterized by their tendency to evaporate easily at room temperature and include substances such as solvents, paint thinners, benzene, butadiene, hexane, toluene, as well as vapors associated with fuels such as gasoline, diesel, heating oil, kerosene, and jet fuel. The GasAlertMicro5 PID’s integrated photoionization detector (PID) enables sensitive broad spectrum monitoring of volatile organic contaminants.
Highly configurable to suit a range of applications, GasAlertMicro5 PID comes as a diffusion or pumped instrument; with either alkaline or NiMH rechargeable hot-swappable battery pack and has optional datalogging capabilities. Standard features include confidence beep, automatic calibration, full function self test, and an extended selection of user-settable field options.
This kit contains everything you need for gas detection in confined spaces. The foam-lined carrying case includes the BW Gas Alert Micro 5-Gas Detector, 34L cylinder of calibration gas required for sensors installed, 1.0 LPM calibration regulator (male) and tubing, Cradle Charger Rechargeable Battery Pack (includes sealed rechargeable nickel-metal hydride (NiMH) battery pack and slip-in charger cradle with 120/230V AC AC/DC adaptor).
Features:
Smaller and over 50% lighter than competitive instruments Water-resistant design in an integral concussion-proof enclosure Continuous LCD shows simultaneous gas concentrations for five gases 0 - 1000 ppm measurement of VOCs (Volatile Organic Compounds) Integral motorized pump option for remote sampling Two power options: AA alkaline or rechargeable hot-swappable battery packs Provides 95 dB alarm tone and two bright wide-angled alarm bars Equipped with internal vibrating alarm for high noise areas Multi-language support in English, French, German, Spanish, and Portuguese Three backlight options: standard-activates in low light (auto), in alarm (auto) and reactivates on-demand; alarm only-activates in alarm conditions and reactivates on-demand; stealth mode Four alarm levels: instantaneous Low and High Alarm for all gases; TWA (time-weighted average) and STEL (short-term exposure limit) for VOCs and toxic gases Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station Records TWA, STEL, and maximum exposures to gas and displays readings on command User selectable fi eld options include: PID / combustible correction factor, language selection, confidence beep, span level, set TWA/ STEL calculation choice, set calibration due date, pass code protection, latching alarm, “SAFE” display function, stealth mode, and selectable ppm resolution for some gases (e.g. SO2 0.1 ppm) Full function self-test of: sensor, battery and circuit integrity; and audible/visual alarms Compatible with BW’s MicroDock II - automated test and calibration station Foam-lined carrying case for instrument and accessories 34L cylinder(s) of calibration gas required for sensors installed 1.0 LPM calibration regulator (male) and tubing Cradle Charger Rechargeable Battery Pack includes: Sealed rechargeable nickel-metal hydride (NiMH) battery pack Slip-in charger cradle with 120/230V AC AC/DC adaptor
Spec Summary:
Auto zero: Yes Calibration: Automatic Backlight: Standard Mode: low light (auto); alarm condition (auto); reactivation on demand Alarm Only Mode: alarm condition (auto); reactivation on demand Stealth Mode: backlight inactive; audible and visual alarms silenced Sensor: PID (VOC) 10.6 eV lamp; plug-in, electrochemical cell (toxic and oxygen); catalytic (LEL) User field options: pass code protection, latching alarms, span level, passed calibration user-lockout option, “SAFE” display function, stealth mode, fast pump, oxygen auto-cal on start-up, alarm only backlight mode, combustible gas measurement (% LEL or % by volume methane), LCD language option, STEL calculation choice, TWA calculation choice, PID / combustible correction factor options, user-settable calibration gas level, high resolution, clock Pump: Tubing length up to 100 ft. / 30 m (50 ft. / 15 m standard) with user options ALARM INDICATORS: Clearly advises alarm conditions with audible, visual, and vibrator alarms Visual alarms: Two flashing alarm bars visible from all angles LCD indicates gas present and alarm levels encountered Audible alarm: Typically 95 dB at 1 ft. / 30 cm variable pulsed audible alarm Vibrator alarm: Pulses warning in gas alarm conditions, or for any status alarms Status alarms: Low battery, over range, multiple gas / pump and failed or missing sensor ALARM LEVELS: Instantaneous Low Alarm for all gases; Instantaneous High Alarm for all gases; TWA (time-weighted average) and STEL (short-term exposure limit) for toxics/VOCs LCD: Continuous, alphanumeric gas readout and status display advises: Gases monitored: VOCs (PID), H2S, CO, O2, SO2, PH3, NO2, NH3, HCN, Cl2, ClO2, O3 and/or combustibles (0-100% LEL or 0-5.0% methane) Gas concentration: Simultaneously and continuously displays gas concentration(s) for all sensors (in ppm, % LEL, or % v/v) Peak (max)/STEL/ TWA ppm or %: Records exposures and displays on demand Alarm setpoints: Displayed on activation and on demand Calibration due date: Days remaining on start-up Clock: Real-time clock setting displayed on start-up TESTS: Full function self-test: Sensor integrity, circuitry, battery and audible/visual alarms on activation Battery: Continuous GENERAL SPECIFICATIONS: Rugged, composite material; two-shot molded polymer case with integral anti-shock boot Operating temperature: 14 to 104oF / -10 to 40oC VOC (PID); -4 to 122oF / -20 to 50oC other gases Humidity: 0 - 95% RH (non-condensing) EMI/RFI: Complies with EMC Directive 89/336/EEC Protection: Highly water resistant and dust proof housing Battery Options: 12 hours on three AA alkaline cells or 10 hours on rechargeable “hot-swappable” battery pack when equipped with PID, oxygen, combustible and TwinTox (H2S/CO) sensor Size: 5.7 x 2.9 x 1.5 in. / 14.5 x 7.4 x 3.8 cm Weight: 13.1 oz. / 370 g WARRANTY: Full 2-year warranty including all sensors (1 year PID lamp and NH3 sensor) DATALOGGER OPTIONS: User-downloadable datalogger Data recorder: All events and occurrences (calibration zero adjustment, calibration span adjustment, gas readings, TWA, STEL, alarm condition, failures detected by the microprocessor). Sampling rate: Factory set at 5-second intervals and user-settable from 1 to 127-second intervals Storage: 2 months of continuous data at 5 second intervals via 32 MB Flash MMC card (64 MB and 128 MB cards also available); when full, the wrap-around feature replaces oldest data with most recent data
BW Technology multi Gas Detector, bw technology Gas Alert Micro, gas detector, gas detection or gas detector, combustible gas detector, gas leak detector, portable gas detector, multi gas detector, detector gas leakage, toxic gas detector, detector gas sewer, combustible gas leak detector, carbon monoxide gas detector, detector de gas, pocket gas detector, co gas detector, combustion gas detector, h2s gas detector, confined detector gas space, handheld gas detector, combustable gas detector, gas monitor, multi gas monitor, combustible gas monitor, portable gas monitor, 4 gas monitor, personal gas monitor, gas detection monitor, o2 gas monitor, oxygen gas monitor, handheld gas monitor, h2s gas monitor, bw gas monitor, carbon monoxide gas monitor, monitor for toxic gas, four gas monitor, bw technologies, bw technology, bw detection gas, bw gas monitor, BW Defender Multi Gas Detector, H2S gas detector, CO gas detector, O2 gas detector, combustibles gas detector, gad detector, bw technology, bw technology defender, multi gas detector, 2 gas detector, 4 gas detector, gas protection, bw technology |
|
 |
 |
|
 |
|
 |

|