The 3M 1860 Health Care Particulate Respirator and Surgical Mask is designed to help provide respiratory protection for the wearer. This product has a filter efficiency level of 95% or greater against particulate aerosols free of oil1. It is fluid resistant, disposable and may be worn in surgery. It can fit a wide range of face sizes. This product contains no components made from natural rubber latex. INTENDED USE: This product meets CDC guidelines for Mycobacterium tuberculosis exposure control. As a respirator, it is intended to reduce wearer exposure to certain airborne particles in a size range of 0.1 to >10.0 microns, including those generated by electrocautery, laser surgery, and other powered medical instruments. As a surgical mask, it is designed to be fluid resistant to splash and spatter of blood and other infectious materials; when worn properly and in combination with protective eyewear, it complies with the OSHA Bloodborne Pathogens Standard. It also provides >99% BFE2 against wearer generated micro-organisms.
CONTRAINDICATIONS: Not for industrial use. Not for use with beards or other facial hair that prevents direct contact between the face and the sealing surface of the respirator. OSHA has not set a permissible exposure level for airborne biohazards.
USE INSTRUCTIONS: 1. Before use for respiratory protection, a written respiratory protection program must be implemented meeting all requirements of OSHA 29 CFR 1910.139 and/or 1910.134 such as medical evaluation, training and fit testing. In Canada, CSA standard Z94.4 requirements must be met. The 3M saccharin (sweet) or Bitrix™ (bitter)qualitative fit test is recommended for this respirator. When used only as a surgical mask, fit testing is not required. 2. Respirator may be used until damaged, breathing becomes difficult, or contaminated with blood or body fluids. Otherwise, it may be stored and reused according to the facility’s infection control policy. 3. Filtering facepieces are to be inspected prior to each use to assure there are no holes in the breathing zone other than the punctures around staples and no damage has occurred. Enlarged holes resulting from ripped or torn filter material around staple punctures are considered damage. Immediately replace respirator if damaged. Staple perforations do not affect NIOSH approval. 4. Discard after every use when used for surgical procedures.
1. PROTECTION N95 - Particulate Filter (95% filter efficiency level) effective against particulate aerosols free of oil; time use restrictions may apply 2. CAUTIONS AND LIMITATIONS A - Not for use in atmospheres containing less than 19.5 percent oxygen. B - Not for use in atmospheres immediately dangerous to life or health. C - Do not exceed maximum use concentrations established by regulatory standards. J - Failure to properly use and maintain this product could result in injury or death. M - All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations. N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer. O - Refer to user's instructions, and/or maintenance manuals for information on use and maintenance of these respirators. P - NIOSH does not evaluate respirators for use as surgical masks.
3m 1860 safety mask n95 surgical, 3m 1860 safety mask surgical, 3m 1860 n95 safety mask, 3m n95 1860 safety safety respirator, 3m n95 surgical safety respirator. 3m Safety Surgical Health Care 1860 N95 Particulate Respirator, 3m Surgical Health Care 1860 N95 SAFETY Particulate Respirator, 3m Surgical Health Care 1860 N95 Particulate Respirator, 3m respirator 1860 N95, 1860 SAFETY 3m, 1860 3m SAFETY mask. 1860 3m mask n95, 1860 3m mask n95 surgical, 1860 3m mask surgical, 1860 3m n95, 1860 3m n95 respirator, 1860 3m respirator, 1860 mask, 1860 mask n95, 1860 mask surgical, 1860 n95, 1860 n95 respirator, 1860 respirator, surgical mask, 3m surgical mask, 3m Respirators, Surgical Mask, 3m respirator 1860 |
|
 |
 |
|
 |
|
 |

|